Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
R Soc Open Sci ; 9(9): 211869, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36147936

RESUMO

Marine organisms normally swim at elevated speeds relative to cruising speeds only during strenuous activity, such as predation or escape. We measured swimming speeds of 29 ram ventilating sharks from 10 species and of three Atlantic bluefin tunas immediately after exhaustive exercise (fighting a capture by hook-and-line) and unexpectedly found all individuals exhibited a uniform mechanical response, with swimming speed initially two times higher than the cruising speeds reached approximately 6 h later. We hypothesized that elevated swimming behaviour is a means to increase energetic demand and drive the removal of lactate accumulated during capture via oxidation. To explore this hypothesis, we estimated the mechanical work that must have been spent by an animal to elevate its swim speed and then showed that the amount of lactate that could have been oxidized to fuel it comprises a significant portion of the amount of lactate normally observed in fishes after exhaustive exercise. An estimate for the full energetic cost of the catch-and-release event ensued.

2.
J Am Coll Cardiol ; 34(1): 204-10, 1999 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10400012

RESUMO

OBJECTIVES: The objective of the study was to determine whether the occurrence of shocks for ventricular tachyarrhythmias during therapy with implantable cardioverter-defibrillators (ICD) is predictive of shortened survival. BACKGROUND: Ventricular tachyarrhythmias eliciting shocks are often associated with depressed ventricular function, making assessment of shocks as an independent risk factor difficult. METHODS: Consecutive patients (n = 421) with a mean follow-up of 756+/-523 days were classified into those who had received no shock (n = 262) or either one of two shock types, defined as single (n = 111) or multiple shocks (n = 48) per arrhythmia episode. Endpoints were all-cause and cardiac deaths. A survival analysis using a stepwise proportional hazards model evaluated the influence of two primary variables, shock type and left ventricular ejection fraction (LVEF <35% or >35%). Covariates analyzed were age, gender, NYHA Class, coronary artery disease, myocardial infarction, coronary revascularization, defibrillation threshold and tachyarrhythmia inducibility. RESULTS: The most complete model retained LVEF (p = 0.005) and age (p = 0.023) for the comparison of any shock versus no shock (p = 0.031). The occurrence of any versus no shock, or of multiple versus single shocks significantly decreased survival at four years, and these differences persisted after adjustment for LVEF. In the LVEF subgroups <35% and <25%, occurrence of multiple versus no shock more than doubled the risk of death. Compared with the most favorable group LVEF > or =35% and no shock, risk in the group multiple shocks and LVEF <35% was increased 16-fold. CONCLUSIONS: In defibrillator recipients, shocks act as potent predictors of survival independent of several other risk factors, particularly ejection fraction.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular/mortalidade , Taquicardia Ventricular/terapia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Fatores de Risco , Volume Sistólico , Análise de Sobrevida , Taquicardia Ventricular/fisiopatologia , Resultado do Tratamento
3.
J Am Coll Cardiol ; 30(3): 769-73, 1997 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-9283538

RESUMO

OBJECTIVES: The objective of this study was to evaluate the feasibility, safety and efficacy of placing implantable cardioverter-defibrillators (ICDs) in the electrophysiology laboratory using conscious sedation with combined hypnotic agents and deep sedation with etomidate. BACKGROUND: Implantable cardioverter-defibrillators with transvenous leads permit the use of simplified implantation techniques similar to those used for the insertion of permanent pacemakers. However, implantation of ICDs without general anesthesia has thus far gained limited acceptance. METHODS: In 162 patients, conscious sedation during ICD placement was achieved with combined intravenous midazolam, morphine and promethazine (Phenergan). Intravenous etomidate was administered to induce deep sedation for defibrillation threshold testing. First-time implantations were in the prepectoral position (n = 142), but some patients with preexisting devices received abdominal implants (n = 20). The results were compared with those of concurrent patients (n = 56) who received prepectoral implants under propofol anesthesia administered by an attending anesthesiologist. RESULTS: The anesthetic protocol was implemented without major intraoperative complications. During deep sedation with etomidate, episodes of apnea, hypoxia or arterial hypotension requiring therapeutic intervention did not occur. During a mean (+/-SD) follow-up period of 257 +/- 140 days (median 227, range 14 to 482), there were, among the 162 patients, a total of two nonsudden cardiac deaths-one 71 days and the other 157 days after the operation. There were two nonsudden deaths in the concurrent control subjects (n = 56)-one 13 days and the other 110 days after the operation. CONCLUSIONS: Implantation of ICDs under conscious sedation with combined hypnotic agents and deep sedation with etomidate is a safe and effective procedure with low perioperative morbidity and low long-term complication rates.


Assuntos
Sedação Consciente , Desfibriladores Implantáveis , Hipnóticos e Sedativos , Prometazina , Idoso , Anestésicos Intravenosos , Etomidato , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Propofol , Estudos Prospectivos
4.
Am J Cardiol ; 79(10): 1408-9, 1997 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-9165170

RESUMO

The question is addressed whether patients with thoracotomy defibrillators and failing epicardial electrodes can be effectively treated with the implantation of prepectoral unipolar ("active can") defibrillators. Results indicate that abandoned epicardial patches in the pathway of unipolar defibrillation currents do not affect defibrillation thresholds and active can efficacy.


Assuntos
Desfibriladores Implantáveis , Eletrodos , Idoso , Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
5.
Am J Cardiol ; 79(6): 820-2, 1997 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-9070572

RESUMO

The database of the registry for an implantable cardioverter defibrillator was analyzed to determine the efficacy and safety of antitachycardia pacing for the termination of ventricular tachycardia. In 22,339 episodes treated, termination occurred in 94% and acceleration in only 1.4%.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular/terapia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Desfibriladores Implantáveis/estatística & dados numéricos , Estudos de Avaliação como Assunto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taquicardia Ventricular/fisiopatologia
6.
Circulation ; 95(4): 946-50, 1997 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-9054755

RESUMO

BACKGROUND: Implantable cardioverter-defibrillators (ICDs) with intravenous electrode systems and downsized generators can be implanted by use of operative techniques similar to those employed for the insertion of permanent pacemakers. However, the safety, efficacy, and long-term follow-up of simplified implantation procedures remain to be evaluated. This report is a prospective long-term evaluation of nonselected patients receiving ICDs in the prepectoral subfascial position under conscious sedation. METHODS AND RESULTS: Clinical characteristics of the 231 consecutive patients included a mean age of 63 years, a male-to-female ratio of 6.4, a left ventricular ejection fraction of 0.34, a mild-to-moderate heart failure in 91%, coronary artery disease in 84%, and a history of aborted sudden cardiac death or refractory ventricular tachyarrhythmias. Insertion of transvenous leads and prepectoral subfascial ICD implantation were performed in electrophysiology laboratories under local anesthesia and conscious sedation with intravenous midazolam and propofol. Successful implantation in all patients (operation time, 80 +/- 32 minutes, mean +/- SD) irrespective of body size and skin thickness was free of major complications, including need for emergency intubation. After surgery, 1 pocket hematoma, 1 seroma, and 1 pneumothorax required treatment. There was no operative or first-month mortality. During long-term follow-up averaging 453 +/- 296 days, six leads required repositioning, but pocket erosions or infections did not occur. First-year total survival was 97%. CONCLUSIONS: Implantation under conscious sedation of ICDs in the prepectoral subfascial position is a safe and effective procedure with low operative and postoperative morbidity and favorable long-term outcome.


Assuntos
Doença das Coronárias/terapia , Desfibriladores Implantáveis , Parada Cardíaca/terapia , Insuficiência Cardíaca/terapia , Fibrilação Ventricular/terapia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Índice de Massa Corporal , Doença das Coronárias/mortalidade , Doença das Coronárias/fisiopatologia , Morte Súbita Cardíaca/prevenção & controle , Desenho de Equipamento , Feminino , Seguimentos , Parada Cardíaca/mortalidade , Parada Cardíaca/fisiopatologia , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Volume Sistólico , Taxa de Sobrevida , Fatores de Tempo , Fibrilação Ventricular/mortalidade , Fibrilação Ventricular/fisiopatologia
7.
Am J Cardiol ; 74(12): 1183-6, 1994 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-7977086

RESUMO

Prospective evaluations of intravenous lidocaine as therapy for sustained monomorphic ventricular tachycardia (VT) in the absence of acute myocardial infarction are lacking. Lidocaine has been promulgated as first-line therapy in patients with VT, but studies evaluating its efficacy in the electrophysiology laboratory suggest that it has poor effects in terminating or preventing induction of VT. Thus, this study sought to evaluate the clinical effectiveness of lidocaine in 3 cohorts with induced or spontaneous VT. One hundred twenty-eight patients with stable VT, occurring either spontaneously or induced at the time of electrophysiologic study either in the baseline state or at the time of pharmacologic testing, were evaluated. The response rate to lidocaine therapy as manifested by termination of VT was the primary goal of the study. Of these patients, 10 (8%) had termination of VT after lidocaine therapy. There were no significant differences in age, ejection fraction, VT cycle length, and mean dose of lidocaine between responders and 118 nonresponders. There were no serious side effects or adverse events (death, myocardial infarction, angina, or congestive heart failure). Lidocaine, although safe, is ineffective in terminating stable VT not associated with acute myocardial infarction.


Assuntos
Doença das Coronárias/complicações , Lidocaína/uso terapêutico , Infarto do Miocárdio/complicações , Taquicardia Ventricular/tratamento farmacológico , Adulto , Idoso , Idoso de 80 Anos ou mais , Estimulação Elétrica , Feminino , Humanos , Injeções Intravenosas , Masculino , Pessoa de Meia-Idade , Taquicardia Ventricular/etiologia , Resultado do Tratamento
8.
Am J Cardiol ; 73(8): 554-8, 1994 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-7511872

RESUMO

The ability of Holter monitoring to predict clinical events during amiodarone therapy was evaluated in 83 patients with coronary artery disease and inducible monomorphic ventricular tachycardia. Sixty-four patients (77%) had significant ventricular ectopy activity (> or = 10 ventricular premature complexes [VPCs]/hour) at baseline, and 19 (23%) did not; patients were similar in age (63 and 65 years, respectively; p = 0.24) and ejection fraction (31 and 32%, respectively; p = 0.75). Over a mean of 23 +/- 17 months, there was no difference in arrhythmia recurrence (33 and 26%; p = 0.89) or sudden death (16 and 20%; p = 0.94) in patients with and without significant ectopy, respectively. In patients with significant ectopy, amiodarone decreased VPC frequency from baseline to 2 weeks, but not from 2 to 6 weeks. Forty-two patients had > 85% reduction in ectopy at 2 weeks; 20 patients did not. However, this reduction of simple VPCs did not predict a decrease in arrhythmic recurrence (29 vs 40%; p = 0.59) nor sudden death (25 vs 11%; p = 0.56) in patients with and without VPC suppression, respectively. Forty-five patients had Holter monitoring at 6 weeks. Twenty-one patients (47%) had > 95% suppression of ectopy, and 24 did not. Neither the recurrence (38 vs 38%; p = 0.54) nor sudden death (33 vs 13%; p = 0.45) rate was predicted by the degree of VPC suppression. Amiodarone is a powerful suppressant of VPCs, but Holter suppression of this ectopic activity is not predictive of clinical outcome.


Assuntos
Amiodarona/uso terapêutico , Complexos Cardíacos Prematuros/tratamento farmacológico , Doença das Coronárias/complicações , Eletrocardiografia Ambulatorial , Taquicardia Ventricular/tratamento farmacológico , Análise Atuarial , Complexos Cardíacos Prematuros/epidemiologia , Complexos Cardíacos Prematuros/etiologia , Morte Súbita Cardíaca/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Recidiva , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/etiologia , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...